TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 434 of 788

TM 9-2350-261-20-4 REPLACE POWER CONTROL ENCLOSURE AC AND DC METERS AND LIGHT INDICATORS (M1068 ONLY) — Continued 0729 00 NOTE Tag all leads before removing them. 3. Remove two nuts (1) and washers (2) from meter M1 (3). 4. Remove two nuts (1) and washers (2) from meter M2 (4). 5. Remove circuits 29A lead (5) and 30A lead (6) from meter M1 (3). 6. Remove circuits 31F lead (7), 32F lead (8), and 28C lead (9) from meter M2 (4). 7. Remove three screws (10), locknuts (11), and meter M1 (3) from faceplate (12). Discard locknuts. 8. Remove three screws (10), locknuts (11), and meter M2 (4) from faceplate (12). Discard locknuts. 9. Remove two jamnuts (13) and lockwashers (14) from two indicator lights (15). Remove lights from faceplate (12). Discard lockwashers. 10. If necessary, remove lens (16) and bulb (17) from indicator light (15). 0729 00-2