TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 433 of 788
TM 9-2350-261-20-4 REPLACE POWER CONTROL ENCLOSURE AC AND DC METERS AND LIGHT INDICATORS (M1068 ONLY) 0729 00 THIS WORK PACKAGE COVERS: Removal (page 0729 00-1). Installation (page 0729 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Primer (WP 0782 00, Item 54) Sealing compound (WP 0782 00, Item 67) Locknut (6) Lockwasher (10) Lockwasher (2) P e r s o n n e l R e q u i r e d Power-Generation Equipment Repairer 52D10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) All external power disconnected (TM 11-7010-256- 12&P) Battery ground lead disconnected (WP 0294 00) REMOVAL 1. Remove ten screws (1), lockwashers (2), and lower faceplate assembly (3) from power enclosure (4). Discard lockwashers. 2. Remove nut (5) and safety cover (6) from terminal 2 on meter M1 (7). Unwrap velcro strap (8) from around local wiring. 0729 00-1