TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 432 of 788

TM 9-2350-261-20-4 REPLACE INVERTER HOUSING A2 TERMINAL BLOCKS TB1 AND TB2 (M1068 ONLY) — Continued 0728 00 INSTALLATION 1. Install terminal block TB2 (7) on cover (4). Secure with four screws (5) and new locknuts (6). 2. Install terminal block TB1 (3) on cover (4). Secure with two screws (1) and new locknuts (2). 3. Connect cable W5 leads E1 through E5 (8) and six inverter leads (9) to terminal block TB2 (7). Use wiring diagram. Secure with ten screws (10). 4. Insert cable W6 lead E2 (11) and two inverter leads E4 (12) into terminal block TB1 (3). Use wiring diagram. Secure with two set screws (13). 5. Install cover (4) on inverter housing (14). Secure with ten screws (15) and new lockwashers (16). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). END OF TASK 0728 00-4