TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 426 of 788

TM 9-2350-261-20-4 REPLACE AC POWER EXTENSION BOX A18 AND BRACKET (M1068 ONLY) — Continued 0726 00 INSTALLATION 1. Install bracket (9) on radio shelf (13). Secure with two screws (10), new lockwashers (11), and nuts (12). 2. Install power extension box A18 (8) on bracket (9). Secure with four screws (5), washers (6), and new locknuts (7). 3. Connect cable W251 plug P2 (3) to power extension box A18 jack J6 (4). 4. Connect cable W252 plug P1 (1) to power extension box A18 jack J1 (2). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). END OF TASK 0726 00-2