TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 375 of 788

TM 9-2350-261-20-4 REPLACE FOG OIL TANK QUICK DISCONNECT TO ADAPTER ACCESS PLATE HOSE (M1059 ONLY) — Continued 0711 00 INSTALLATION NOTE Left and right hoses are replaced the same way. 1. Remove safety cap (1) from hose (2) and dust cap (3) from quick disconnect coupling (4). 2. Connect fog oil hose assembly (2) to fog oil tank quick disconnect coupling (4). 3. Connect fog oil hose assembly (2) to access plate adapter (5). 4. Secure hose assembly (2) to hull with four clamps (6), screws (7), and new lockwashers (8) (right side: secure with five clamps, screws, and new lockwashers). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). 2. Set circuit breaker CB1 to ON. See TM 3-1040-283-10. END OF TASK 0711 00-3/4 blank