TM 9-2350-261-20-4 REPLACE ADAPTER ACCESS PLATE TO GENERATOR ELECTRICAL CABLE ASSEMBLY (M1059 ONLY) — Continued 0703 00 INSTALLATION WARNING Before you do any maintenance, discharge all capacitors to ground or electrical shock could injure personnel. NOTE Left and right cable assemblies are replaced the same way. 1. Connect cable assembly (1) to smoke generator cover assembly connector 5J1 (3). 2. Connect cable assembly (1) to adapter access plate connector (2). FOLLOW-THROUGH STEPS 1. Install smoke generator assembly on bracket (WP 0697 00). 2. Install inboard armor shield (WP 0713 00). 3. Connect battery ground lead (WP 0294 00). 4. Set circuit breaker CB1 to ON. See TM 3-1040-283-10. END OF TASK 0703 00-3/4 blank