TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 340 of 788
TM 9-2350-261-20-4 REPLACE SMOKE GENERATOR INTERNAL CABLE ASSEMBLY (M1059 ONLY) — Continued 0702 00 3. Install cable (1), six clamps (7), screws (8), and new lockwashers (9) on hull. 4. Connect cable (1) to jack 1J3 (left) (10) or 1J4 (right) (11) on back of control panel (12). FOLLOW-THROUGH STEPS 1. Install smoke generator assembly on bracket (WP 0697 00). 2. Install inboard armor shield (WP 0713 00). 3. Connect battery ground lead (WP 0294 00). 4. Set circuit breaker CB1 to ON. See TM 3-1040-283-10. END OF TASK 0702 00-4