TM 9-2350-261-20-4 REPLACE SMOKE GENERATOR INTERNAL CABLE ASSEMBLY (M1059 ONLY) — Continued 0702 00 INSTALLATION WARNING Before you do any maintenance, discharge all capacitors to ground or electrical shock could injure personnel. NOTE Left and right cable assemblies are replaced the same way, except left side cable assembly has six clamps and right side has only one. Left side is shown. 1. Install cable (1), dust cap (2), four screws (3), and new locknuts (4) on access plate (5). 2. Install connector (6) to cable (1) on access plate (5). 0702 00-3