TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 326 of 788
TM 9-2350-261-20-4 REPLACE SMOKE GENERATOR SYSTEM POWER SUPPLY CABLE ASSEMBLY (M1059 ONLY) — Continued 0699 00 1. Disconnect cable assembly (1) from control panel assembly connector 1J1 (2). 2. Remove screw (3), two washers (4), lockwasher (5), locknut (6), and ground lead (7) from hull bracket. Discard lockwasher and locknut. 3. Remove screw (8), nut (9), and cable assembly (1) from positive battery terminal (10). 4. Remove cable assembly (1) and grommet (11) from battery box (12). Discard grommet. 5. Remove six screws (13), lockwashers (14), and 12 clamps (15) from cable assembly (16). Discard lockwashers. 6. Remove two screws (17), lockwashers (18), clamps (19), and cable assembly (16) from hull. Discard lockwashers. 0699 00-2