TM 9-2350-261-20-4 REPLACE SMOKE GENERATOR CONTROL PANEL ASSEMBLY (M1059 ONLY) — Continued 0698 00 5. Connect fog oil pump cable assembly (1) to control panel assembly connector marked 1J5 (2). 6. Connect air compressor cable assembly (3) to control panel assembly connector marked 1J2 (4). 7. Connect smoke generator number 1 (right) cable assembly (5) to control panel assembly connector marked 1J3 (6). 8. Connect smoke generator number 2 (left) cable assembly (7) to control panel assembly connector marked 1J4 (8). 9. Connect main power cable assembly (9) to control panel assembly connector marked 1J1 (10). 10. Connect glow plug cable (11) to control panel assembly connector marked 1J6 (12). 0698 00-4