TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 320 of 788
TM 9-2350-261-20-4 REPLACE SMOKE GENERATOR CONTROL PANEL ASSEMBLY (M1059 ONLY) — Continued 0698 00 REMOVAL WARNING Before you do any maintenance, discharge all capacitors to ground or electrical shock could injure personnel. NOTE Tag all cables to match their respective connectors before removal. 1. Disconnect six cable assembly plugs (1) from control panel (2). Install associated dust caps (3). 2. Remove four screws (4), lockwashers (5), eight washers (6), four locknuts (7), and control panel (2) with two attached brackets (9) and (11) from two brackets (8) and (10). Discard lockwashers and locknuts. 3. Remove eight screws (12), lockwashers (13) and two brackets (9) and (11) from control panel (2). Discard lockwashers. 4. Remove four screws (14), washers (15), and two brackets (8) and (10) from carrier. 0698 00-2