TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 236 of 788

TM 9-2350-261-20-4 REPLACE M13 PRECLEANER AND FRAME (M1068 ONLY) — Continued 0680 00 INSTALLATION NOTE The precleaner must be adjusted before installation. See TM 3-6680-316-10. 1. Install new lockwashers (1), four screws (2), and frame (3) on mounting bracket (4). 2. Install precleaner (5) in frame (3) and secure with latch (6). 3. Install two hoses (7) and (8) and clamps (9) on precleaner (5). Tighten clamps. 4. Install circuit lead 538A (10) with ground lead (11) on precleaner (5). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). END OF TASK 0680 00-2