TM-9-2350-261-20-4 Unit Maintenance Manual Volume 4 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 119 of 788
TM 9-2350-261-20-4 REPLACE COOLANT HEATER AND PUMP UNIT — Continued 0650 00 8. Align bracket (1) with four hull brackets. Secure with two screws (2), new lockwashers (3), and flat washers (4) in outboard end of bracket (1) and brackets on hull. 9. Install two screws (5), and two flat washers (6) in inboard end of bracket (1) and brackets on hull. 10. Install fuel supply hose (7) on elbow (8). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). 2. Fill carrier cooling system (WP 0194 00). 3. Open personnel heater fuel shutoff valve (see your -10). 4. Start coolant heater (see your -10). Check to make sure heater is installed right. Check for leaks. Turn heater off. 5. Close power plant front access door (see your -10). 6. Raise trim vane (see your -10). END OF TASK 0650 00-7/8 blank