TM-9-2350-261-20-3 Unit Maintenance Manual Volume 3 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 90 of 936
TM 9-2350-261-20-3 REPLACE FLOOR PLATES (M901A1 ONLY) — Continued 0441 00 INSTALLATION 1. Install two floor plate cleats (14) on floor plate (15). Secure with six screws (11), flat washers (12), and new locknuts (13). 2. Install two left floor plate cleats (9) on floor plate (10). Secure with four screws (6), flat washers (7), and new locknuts (8). 3. Install two tread plate cleats (4) on floor plate (5). Secure with four screws (1), flat washers (2), and new locknuts (3). WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 4. Apply light coat of adhesive to groove portion of new grommet (16). Allow adhesive to dry until tacky. 5. Carefully insert new grommet (16) in cut out portion of floor plate (10). Press firmly into place. Wipe off excess sealant. 0441 00-4