TM-9-2350-261-20-3 Unit Maintenance Manual Volume 3 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 795 of 936
REPAIR PERSONNEL HEATER CONTROL BOX — Continued 3. Remove RUN-OFF-START switch (11) from control box (13). a. Remove six screws (1), lockwashers (2), jumper 15-17 (3), jumper 13-20 (4), lead 20-C (5), lead 14-A (6), jumper 21-18 (7), jumper 21-14 (8), lead 19-2 (9), and lead 19-E (10) from RUN-OFF-START switch (11). b. Remove two screws (12) and RUN-OFF-START switch (11) from control box (13). 4. Remove HI-LO heat switch (16) from control box (13). a. Remove nut (14), lockwasher (15), instruction plate (if applicable), and HI-LO switch (16) from control box (13). b. Remove two screws (17), lockwashers (18), jumper 13-20 (4), and lead 12-B (19) from HI-LO switch (16). 0614 00-3 0614 00 TM 9-2350-261-20-3