TM-9-2350-261-20-3 Unit Maintenance Manual Volume 3 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 773 of 936

TM 9-2350-261-20-3 REPLACE PERSONNEL HEATER FUEL FILTER, HOSES, AND FITTINGS (M1064 ONLY) — Continued 0609 00 9. Install three new tie straps (1) on hose assembly (2). FOLLOW-THROUGH STEPS 1. Open heater fuel shutoff valve (see your -10). 2. Connect battery ground strap (WP 0294 00). 3. Bleed fuel line (WP 0599 00). 4. Start heater (see your -10). Check all fittings for leaks. Turn heater off. 5. Install front floor plates (WP 0437 00). 6. Install heater duct (WP 0617 00). 7. Start engine (see your -10). 8. Raise and lock ramp (see your -10). 9. Stop engine (see your -10). END OF TASK 0609 00-7/8 blank