TM-9-2350-261-20-3 Unit Maintenance Manual Volume 3 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 724 of 936

SERVICE PERSONNEL HEATER FUEL FILTER — Continued INSTALLATION 1. Install new preformed packing (2) on new filter element (3). 2. Install collector bowl (1) in new filter element (3). 3. If head gasket (4) was removed, position same gasket in filter head (5) or on filter element (3). 4. Install new filter element (3) and gasket (4) on head bolt (6) and filter head (5). 5. Install shield (7), four screws (8), new lockwashers (9), and washers (10) on sponson over fuel filter/water separator assembly. FOLLOW-THROUGH STEPS 1. Turn personnel heater fuel valve ON (see your -10). 2. Turn personnel heater ON (see your -10). Check for leaks. 3. Turn personnel heater OFF (see your -10). END OF TASK 0598 00-4 0598 00 TM 9-2350-261-20-3