TM-9-2350-261-20-3 Unit Maintenance Manual Volume 3 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 666 of 936

TM 9-2350-261-20-3 REPLACE QUICK DISCONNECT AND RAMP CONTROL VALVE TUBE TO BULKHEAD CONNECTION — Continued 0587 00 REMOVAL 1. Remove four screws (1), washers (2), and clamps (3) on tube (4), and clamp (5) on tachometer cable (6) from four bulkhead weldnuts. 2. Remove four clamps (3) from tube (4). WARNING Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested. Do not service hydraulic system when FRH is hot or pressurized. Wear gloves and avoid contact with skin. If FRH contacts skin, wash immediately with soap. If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention. If FRH is swallowed, get medical attention. 3. Remove tube (4) from ramp control valve (7) and quick disconnect (8). 4. Remove four locknuts (9), clamps (10), and screws (11) from power plant compartment bulkhead. Discard locknuts. 5. Remove tube (4) from ramp control valve (7) and bulkhead elbow (12). 0587 00-2