TM 9-2350-261-20-3 REPLACE RAMP CONTROL VALVE TO HYDRAULIC TANK HOSE — Continued 0583 00 FOLLOW-THROUGH STEPS WARNING Loose clothing is dangerous around moving belts and pulleys. You could get badly hurt if your clothes get caught in moving parts. WARNING An inoperable/unsafe ramp can fall and kill soldiers. Seal off area behind ramp during testing and bleeding of hydraulic lines. 1. Fill hydraulic tank (WP 0120 00). 2. Start engine (see your -10). Check for hydraulic leaks. 3. Raise and lower ramp several times to bleed air from system (see your -10). 4. Install power plant rear access panel (WP 0431 00 or WP 0433 00). 5. Raise and lock ramp (see your -10). 6. Stop/shutdown engine (see your -10). END OF TASK 0583 00-4