TM-9-2350-261-20-3 Unit Maintenance Manual Volume 3 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 647 of 936

TM 9-2350-261-20-3 REPLACE RAMP CONTROL VALVE TO HYDRAULIC TANK HOSE — Continued 0583 00 INSTALLATION 1. Install quick disconnect assembly (7) on adapter (8). WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 2. Apply sealing compound to male threads of hose (5). Install hose on quick disconnect assembly (7) and elbow (6). 3. Place two clamps (3) on hose (5). Align clamps with oil filter bracket screws (4). Secure with two washers (2) and new locknuts (1). 0583 00-3