TM-9-2350-261-20-3 Unit Maintenance Manual Volume 3 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 636 of 936
TM 9-2350-261-20-3 REPLACE RAMP PUMP TO PRESSURE RELIEF VALVE HOSE — Continued 0581 00 REMOVAL 1. Remove screw (1), clamp (2), and locknut (3) from clamp (4) on ramp-to-strainer tube (5). Remove clamp (2) from hose (6). Discard locknut. 2. Remove screw (7), tab washer (8), and clamp (9) from transfer gearcase. Discard tab washer. 3. Remove clamp (9) from hose (6). WARNING Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested. Do not service hydraulic system when FRH is hot or pressurized. Wear gloves and avoid contact with skin. If FRH contacts skin, wash immediately with soap. If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention. If FRH is swallowed, get medical attention. 4. Remove hose (6) from ramp pump elbow (10) and tee (11). 0581 00-2