TM-9-2350-261-20-3 Unit Maintenance Manual Volume 3 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 613 of 936

TM 9-2350-261-20-3 REPLACE SMOKE GRENADE LAUNCHER WIRING HARNESS (M113A2, M1059, AND M901A1 ONLY) — Continued 0577 00 19. Install cover (1) on connector (2). 20. Install wiring harness (7). 21. Install washer insulator (3), washer (4), new lockwasher (5), and new locknut (6) on wiring harness (7). 22. Install rubber bushing (8), end seal plug (9), packing retainer (10), spring washer (11), and coupling nut (12) on wiring harness (7). 23. Feed wiring harness (7) through bushing (13) and secure with washer (14), new lockwasher (15), and new locknut (16). 24. Install connectors (17) and (18) on wiring harness. 25. Connect circuit 7 lead (17) and circuit 799 lead (18) inside carrier. 26. Repeat Steps 19 - 25 for opposite side of carrier. FOLLOW-THROUGH STEPS 1. Install base and plate (WP 0576 00). 2. Close power plant front access door and raise trim vane (see your -10). 3. Connect battery ground lead (WP 0294 00). END OF TASK 0577 00-11/12 blank