TM-9-2350-261-20-3 Unit Maintenance Manual Volume 3 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 604 of 936
TM 9-2350-261-20-3 REPLACE SMOKE GRENADE LAUNCHER WIRING HARNESS (M113A2, M1059, AND M901A1 ONLY) — Continued 0577 00 REMOVAL 1. Disconnect circuit 7 lead (1) and circuit 799 lead (2) from inside carrier. 2. Remove locknut (3), lockwasher (4), and washer (5) from bushing (6) and wiring harness (7). Discard locknut and lockwasher. 3. Remove coupling nut (8), spring washer (9), packing retainer (10), end seal plug (11), and rubber bushing (12) from bushing (6). 4. Remove locknut (13), lockwasher (14), washer (15), and washer insulator (16) from bushing (6). Discard locknut and lockwasher. 5. Remove harness (7) from hull. 6. Remove cover (17) from connector (18). 7. Repeat Steps 1 - 6 for opposite side of carrier. 0577 00-2