Page 568 of 936

REPLACE RAMP DOOR SEAL — Continued INSTALLATION 1. Place door seal (3) on door (2). 2. Bend five retainer strips (1) on door (2) down on seal (3) to secure in place. FOLLOW-THROUGH STEPS 1. Close ramp door to check that ramp door seal works right (see your -10). 2. Perform chalk test (WP 0556 00). END OF TASK 0566 00-2 0566 00 TM 9-2350-261-20-3