TM 9-2350-261-20-3 ADJUST RAMP LOCK (M577A2 AND M1068 ONLY) — Continued 0561 00 8. Tighten locknut (1) on setscrew (2). NOTE After attaching clevis to the arm, make sure arm is still against the setscrews. 9. Align clevis (5) with arm (6). Secure with headed pin (7) and new cotter pin (8). 10. Loosen two nuts (9) on cable (10) at bracket (11). 11. Adjust length of cable (10) to obtain 1-7/8 inches (5 cm) clearance between nut (12) and seal (13). Tighten two nuts (9). 0561 00-4