TM 9-2350-261-20-3 REPLACE POWER PLANT DOOR — Continued 0427 00 WARNING Hanging loads, heavy parts, and overhead equipment can fall unexpectedly and kill or injure you. Stay clear of hanging loads, heavy parts, and overhead equipment. Use correct lifting devices. Always have helper guide heavy parts and equipment. 1. Connect a suitable lifting device and sling around power plant door. Hold door straight up until tension is gone. Have helper assist. 2. Remove four screws (1), washers (2), two brackets (3) and (4), plates (5), and power plant door (6) from hull. 3. Remove two spacers (7) from ends of power plant door (6). 0427 00-2