TM-9-2350-261-20-3 Unit Maintenance Manual Volume 3 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 43 of 936
TM 9-2350-261-20-3 REPLACE POWER PLANT DOOR COMBAT LOCK 0426 00 THIS WORK PACKAGE COVERS: Removal (page 0426 00-1). Installation (page 0426 00-2). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Drive pin Locknut (16) P e r s o n n e l R e q u i r e d Unit Mechanic Helper (H) E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Trim vane lowered and disconnected (see your -10) Power plant door open (see your -10) Battery ground lead disconnected (WP 0294 00) REMOVAL NOTE Tag or mark each harness to make sure each is installed in the proper connector after service. 1. Disconnect four wiring harnesses (1) from bulkhead connectors (2) inside driver’s compartment. 2. Remove 16 locknuts (3) and screws (4), and four wiring harness connectors (2) from bulkhead. Discard locknuts. 3. (H): Hold hand under bolt (5) from inside carrier through power plant access door opening. 4. Drive out pin (6). Remove handle (7) and spring (8) from bolt (5). Discard drive pin. 5. (H): Remove bolt (5) from power plant compartment. 0426 00-1