TM 9-2350-261-20-3 REPLACE SPARE IR (M19) PERISCOPE STOWAGE BOX — Continued 0526 00 INSTALLATION WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 1. If any pad was removed, apply a thin coat of adhesive to pad. Allow to dry 20 to 40 minutes. Apply thin, even coat of adhesive to metal surface. Allow to dry 30 seconds to 2 minutes. Press surfaces firmly together. 2. Align periscope stowage box (3) with driver’s sponson. Secure with four new lockwashers (2) and screws (1). END OF TASK 0526 00-2