TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 85 of 1012

TM 9-2350-261-20-2 REPLACE FAN DRIVE ADJUSTABLE IDLER AND PULLEY — Continued 0213 00 9. Secure fan idler pulley (3) to arm (9) with nut (18), washer (19), and bolt (20). TIGHTEN NUT TO 50-55 LB-FT (68-75 N·M) TORQUE. Use torque wrench. 10. Install and adjust fan drive belts (WP 0211 00). FOLLOW-THROUGH STEPS WARNING Wearing loose clothing around moving parts can allow personnel to get caught and cause injury or death. Tuck in loose clothing. 1. Start engine (see your -10). Check adjustable idler and fan drive belts for proper operation. 2. Raise and lock ramp (see your -10). 3. Engine stopped/shutdown (see your -10). 4. Install power plant rear access panel (WP 0431 00, WP 0432 00, or WP 0433 00). END OF TASK 0213 00-3/4 blank