TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 70 of 1012
TM 9-2350-261-20-2 REPLACE AUXILIARY TANK TO RADIATOR TUBE — Continued 0208 00 INSTALLATION WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 1. Apply a thin, even coat of sealing compound to external threads of two adapters (3). 2. Install two adapters (3) in auxiliary tank (4) and radiator (5). 3. Secure hose (2) to two adapters (3) with two clamps (1). 0208 00-2