TM 9-2350-261-20-2 REPLACE DIFFERENTIAL OIL PUMP TO DIFFERENTIAL HOSE AND FITTINGS — Continued 0358 00 9. Connect hose (4) to elbow (16). 10. Connect oil hose quick disconnect coupling (18). 11. Install differential high oil temperature switch (WP 0318 00). 12. Fill differential with oil (WP 0120 00). WARNING Loose clothing is dangerous around moving belts and pulleys. You could get badly hurt if your clothes get caught in moving parts. 13. Start engine (see your -10). Check for oil leaks. FOLLOW-THROUGH STEPS 1. Engine stopped/shutdown (see your -10). 2. Install hull bottom access cover (WP 0434 00). 3. Close power plant front access door (see your -10). 4. Raise trim vane (see your -10). END OF TASK 0358 00-3/4 blank