TM 9-2350-261-20-2 REPLACE AUXILIARY TANK TO COOLANT PUMP TUBE 0207 00 THIS WORK PACKAGE COVERS: Removal (page 0207 00-1). Installation (page 0207 00-2). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Sealing compound (WP 0782 00, Item 60) P e r s o n n e l R e q u i r e d Unit Mechanic E q u i p m e n t C o n d i t i o n Engine stopped/shutdown (see your -10) Carrier blocked (see your -10) Trim vane lowered and power plant front access door open (see your -10) Drain cooling system (WP 0193 00) REMOVAL 1. Remove screw (1), washer (2), and clamp (3) from bracket (4). 2. Loosen two clamps (5). Disconnect hose (6) from adapter (7) and tube (8). 3. Loosen two clamps (9). Disconnect hose (10) from tube (8) and auxiliary tank (11). 4. Remove adapter (7) from oil cooler elbow (12). 5. Remove tube (8) from carrier, and clamp (3) from tube. 0207 00-1