TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 64 of 1012

TM 9-2350-261-20-2 REPLACE AUXILIARY TANK AND PARTS — Continued 0206 00 WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 5. Apply thin coat of sealing compound (WP 0782 00, Item 60) to external threads of adapter (11) and two elbows (12). 6. Install adapter (11) and two elbows (12) in auxiliary tank. 8. Secure three hoses (15) to auxiliary tank with three clamps (16). FOLLOW-THROUGH STEPS 1. Lower power plant grill (WP 0130 00). 2. Start engine (see your -10). Check for leaks. 3. Stop/shutdown engine (see your -10). END OF TASK 0206 00-4 7. Secure auxiliary tank to power plant grill with four screws (13) and washers (14). TIGHTEN SCREWS TO 264-288 LB-IN (30-33 N·M) TORQUE. Use torque wrench and socket wrench set.