TM 9-2350-261-20-2 REPLACE AUXILIARY TANK AND PARTS — Continued 0206 00 INSTALLATION WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 1. Apply thin coat of sealing compound (WP 0782 00, Item 62) to both sides of new gasket (1). 2. Install new gasket (1), filler neck (2), and bracket (3) on auxiliary tank (4). Secure with four screws (5), flat washers (6), and new lockwashers (7). 3. Secure chain (8) to bracket (3) and filler cap (9) with two hooks (10). 4. Install filler cap (9) in filler neck (2). 0206 00-3