TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 626 of 1012
TM 9-2350-261-20-2 REPLACE TRANSFER GEARCASE OIL FILLER — Continued 0344 00 1. Clean oil filler with cleaning compound. 2. Check oil filler. Repair damaged oil filler (WP 0345 00). INSTALLATION WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 1. Apply a thin, even coat of sealing compound to cleaned base of oil filler (2). 2. Install oil filler (2) in transfer gearcase (3) and secure with new rivet (1). FOLLOW-THROUGH STEPS 1. Install power plant rear access panels (WP 0431 00, WP 0432 00, or WP 0433 00). 2. Install driver’s power plant access panel (WP 0430 00). END OF TASK 0344 00-2 CLEAN, INSPECT, AND REPAIR