TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 602 of 1012

TM 9-2350-261-20-2 REPLACE FUEL QUANTITY SELECTOR SWITCH (M577A2 AND M1068 ONLY) — Continued 0337 00 INSTALLATION 1. Place switch (9) on rear of master switch panel (4). Secure with two screws (10). 2. Connect circuit 30 (8), circuit 29 (7), and circuit 28 (6) leads to rear of switch (9). 3. Place panel (4) on distribution box (5). Secure with eight screws (3), washers (2), and new locknuts (1). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). 2. Turn MASTER SWITCH to ON (see your -10). 3. Check for fuel quantity readings on both tanks (see your -10). 4. Turn all switches OFF (see your -10). END OF TASK 0337 00-2