TM 9-2350-261-20-2 REPAIR RADIATOR ACCESS DOOR 0205 00 THIS WORK PACKAGE COVERS: Disassembly ( page 02 05 00 -1 ). Assembly ( pag e 0 205 0 0-2 ). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Locknut (4) P e r s o n n e l R e q u i r e d Unit Mechanic E q u i p m e n t C o n d i t i o n Engine stopped/shutdown Carrier blocked (see your -10) Driver’s power plant access panel removed (WP 0430 00) DISASSEMBLY 1. Loosen two thumbscrews (1) and clamps (2). Remove radiator access panel (3) from power plant compartment bulkhead. 2. Release two fasteners (4) on access door (5) and lower access door. 3. Remove four screws (6), flat washers (7), and locknuts (8). Remove access door (5). Discard four locknuts. 0205 00-1