TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 551 of 1012
TM 9-2350-261-20-2 REPLACE POWER PLANT WIRING HARNESS — Continued 0321 00 INSTALLATION 1. Install power plant wiring harness (8) on power plant. Secure with three straps (7), eight nuts (6), eight clamps (5), and 11 screws (4). 2. Connect circuit 1, 2, 3, and 3A lead (1) to generator (2). 3. Connect circuit 406-406A lead (3) to air box heater wiring harness. 0321 00-5