TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 532 of 1012

TM 9-2350-261-20-2 REPAIR CABLE ASSEMBLY — Continued 0314 00 CLEAN, INSPECT, AND REPAIR 1. Check wire leads. Look for damaged insulation or broken wires. If wire leads have been taped together, remove tape. Scrape wire lead covering with your thumbnail to see if covering peels off. Replace bad leads. 2. Check contact pins, contact sockets, and terminals. Replace burned, bent, or broken parts. 3. Check shells, sleeves, and nipples. Replace cut, torn, or damaged parts. NOTE If replacing lead, cut new wire from bulk supply. Measure original length, gauge, and type of wire. 1. Strip insulation from leads of cable (1) to expose just enough wire to fill holes in contacts (2). 2. Slide retaining nut (3) and coupling nut (4) on cable (1). 3. Push leads of cable (1) through grommet (5) and insert in new contacts (2). NOTE Make sure leads pass through proper lettered holes in grommet. 4. Solder leads of cable (1) in contacts (2) and press contacts into grommet (5). Use soldering gun. 5. Align and install grommet (5) in plug (6). Secure with retaining nut (3). FOLLOW-THROUGH STEPS 1. Use multimeter to perform continuity check before connecting batteries. 2. Connect battery ground lead (WP 0294 00). 3. Turn MASTER SWITCH to ON to check for proper cable repair. 4. Turn MASTER SWITCH to OFF (see your -10). END OF TASK 0314 00-2 ASSEMBLY