TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 530 of 1012

TM 9-2350-261-20-2 REPAIR RECEPTACLE — Continued 0313 00 CLEAN, INSPECT, AND REPAIR 1. Check wire leads. Look for damaged insulation or broken wires. If wire leads have been taped together, remove tape. Scrape wire lead covering with your thumbnail to see if covering peels off. Replace bad leads. 2. Check contact pins, contact sockets, and terminals. Replace burned, bent, or broken parts. 3. Check shells, sleeves, and nipples. Replace cut, torn, or damaged parts. ASSEMBLY NOTE If replacing lead, cut new wire from bulk supply. Measure original length, gauge, and type of wire. 1. Slide nut (1) over leads (2). 2. Strip insulation from leads (2) to expose just enough wire to fill holes in contacts (3). 3. Push leads (2) through grommet (4) and insert in new contacts (3). Solder leads (2) in contacts (3). Use soldering gun. NOTE Make sure leads pass through proper lettered holes in grommet. 4. Align and install grommet (4) in receptacle (5). Secure with nut (1). FOLLOW-THROUGH STEPS 1. Use multimeter to perform continuity check before connecting batteries. 2. Connect battery ground lead (WP 0294 00). 3. Turn MASTER SWITCH to ON to check for proper receptacle repair. 4. Turn MASTER SWITCH to OFF (see your -10). END OF TASK 0313 00-2