TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 528 of 1012
TM 9-2350-261-20-2 REPAIR WIRING HARNESS — Continued 0312 00 5. If removed, install Y-type adapters and dummy plugs. a. Install Y-type adapter (3) on harness leads (4). b. Install dummy plugs (5) in male or female connector (6). FOLLOW-THROUGH STEPS 1. Use multimeter to perform continuity check before connecting batteries. 2. Connect battery ground lead (WP 0294 00). END OF TASK 0312 00-6