TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 475 of 1012
TM 9-2350-261-20-2 REPLACE CIRCUIT 6 LEAD (ALL EXCEPT M577A2 AND M1068) — Continued 0301 00 1. Clean lead terminals and mating surfaces with terminal cleaner. 2. Check leads. Replace worn leads and damaged connectors (WP 0312 00). INSTALLATION 1. Route circuit 6 lead (12) through hull support channel. 2. Install new grommet (15) on lead (12). Install lead and grommet in master switch panel (9). 3. Place lead (12) on master switch bus bar (14). Secure with screw (13) and nut (11). 4. Place panel (9) on distribution box (10). Secure with eight washers (7), screws (8), and nuts (6). 5. On M113A2 and M901A1 carriers, install five cradles (5) on hull weldnuts. Secure with five screws (7). Place lead (12) in five cradles and secure with clips (6). 0301 00-3 Do not start carriers while batteries are disconnected. Starting engine with outside power will damage electrical components in the regulator. C N A O U I T