TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 465 of 1012
TM 9-2350-261-20-2 REMOVE/INSTALL BATTERY LEADS (M577A2 ONLY) 0299 00 THIS WORK PACKAGE COVERS: Removal (page 0299 00-1). Clean, Inspect, and Repair (page 0299 00-2). Installation (page 0299 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s Battery Terminal Cleaner (WP 0780 00, Item 12) Battery Terminal Puller (WP 0780 00, Item 47) General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Grease (WP 0782 00, Item 24) Sod ium bicarbon ate (W P 07 82 00 , Item 70 ) Grommet (3) P e r s o n n e l R e q u i r e d Unit Mechanic E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Ramp lowered (see your -10) Battery access cover removed (WP 0297 00) REMOVAL WARNING Gas from batteries can explode. Ventilate compartment before you disconnect or connect battery cables. Battery acid can burn or blind you. Do not get acid on your skin or eyes. ALWAYS disconnect ground lead (circuit 7) first and connect it last. WARNING Electrical current can burn you. Disconnect battery ground lead before you start task. C A U T I O N Do not start carriers without batteries installed. Starting engine with outside power will cause damage to electrical components in the regulator. 0299 00-1