TM 9-2350-261-20-2 REMOVE/INSTALL BATTERY LEADS (M1068 ONLY) — Continued 0298 00 3. Install jumper lead (17) as follows: a. Install jumper lead (17) on battery negative terminal (2). Secure with screw (12) and nut (13). b. Install jumper lead (17) on battery positive terminal (1). Secure with screw (12) and nut (13). 4. Coat tops of four battery terminals (1) and (2) with grease. FOLLOW-THROUGH STEPS 1. Install battery access cover (WP 0297 00). 2. Connect battery ground lead (WP 0294 00). 3. Turn MASTER SWITCH to ON. Check BATT-GEN gauge on instrument panel. Gauge should read in BATT green or yellow zone (see your -10). 4. Start engine (see your -10). 5. Raise and lock ramp (see your -10). 6. Turn MASTER SWITCH to OFF (see your -10). END OF TASK 0298 00-5/6 blank