TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 448 of 1012
TM 9-2350-261-20-2 DISCONNECT/CONNECT BATTERY GROUND LEAD — Continued 0294 00 1. Loosen nut (1) and remove circuit 7 ground lead and terminal lug (2) from battery post (3). Use battery terminal puller. CONNECT C A U T I O N Battery cells can be damaged if the batteries are connected incorrectly. Be sure batteries are connected correctly. 1. Position circuit 7 ground lead and terminal lug (2) on battery post (3) and tighten nut (1). 2. Coat top of battery post (3) and terminal lug (2) with grease. FOLLOW-THROUGH STEPS 1. Secure battery (see your -10). 2. Start engine (see your -10). 3. Raise and lock ramp (see your -10). 4. Stop/shutdown engine (see your -10). END OF TASK 0294 00-2