TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 44 of 1012

TM 9-2350-261-20-2 REPLACE THERMOSTAT HOUSING TO ENGINE COOLANT TUBE — Continued 0201 00 INSTALLATION WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. NOTE If plug (11) was removed, clean and apply a thin coat of sealing compound (WP 0782 00, Item 60) on threads before installing. 1. Connect coolant tube (1) to hose (2) with two clamps (3). Tighten two clamps (3). 2. Connect coolant tube (1) and elbow (4) with hose (5) and two clamps (6). Tighten two clamps (6). 3. Apply a thin coat of sealing compound (WP 0782 00, Item 62) to both sides of new gasket (7). FOLLOW-THROUGH STEPS 1. Fill cooling system (WP 0194 00). 2. Start engine (see your -10). Check for leaks. 3. Stop/shutdown engine (see your -10). 4. Close power plant front access door and raise trim vane (see your -10). END OF TASK 0201 00-2 4. Install new gasket (7) between elbow (4) and engine. Secure with two flat washers (8), new lockwashers (9), and screws (10). TIGHTEN SCREWS TO 360-384 LB-IN (41-43 N·M) TORQUE. Use torque wrench.