TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 400 of 1012

REPLACE REAR MAIN WIRING HARNESS (M1064 ONLY) — Continued 4. Connect circuit 450 lead (1) to lower circuit breaker (6). 5. Install circuit 400 lead (7) and new grommet (8) in distribution box (4). 6. Install circuit 6 (9), circuit 2 (10), and circuit 400 (7) leads on bus bar (11) on master switch (12). Secure with screw (13) and new locknut (14). NOTE Inspect gasket on distribution box. Replace if damaged. 7. Install master switch panel (15) on distribution box (4). Secure with eight screws (16), washers (17), and new locknuts (18). 8. Connect circuit 37 lead (19) to master switch panel lead (20). 0288 00-14 0288 00 TM 9-2350-261-20-2