TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 398 of 1012
TM 9-2350-261-20-2 REPLACE REAR MAIN WIRING HARNESS (M1064 ONLY) — Continued 0288 00 0288 00-12 NOTE The 200 amp and 100 amp distribution boxes are similar. Removal of most lead wires are the same. 200 amp is shown. Do Step 52 for 200 amp only. 52. Disconnect circuit 37 lead (1) from master switch panel lead (2). 53. Remove eight screws (3), washers (4), and locknuts (5) from master switch panel (6). Separate panel from distribution box (7). Discard locknuts. 54. Remove locknut (8), screw (9), circuit 400 (10), circuit 2 (11), and circuit 6 (12) leads from bus bar (13) on master switch (14). Discard locknut. 55. Remove circuit 400 lead (10) and grommet (15) from distribution box (7). Discard grommet. 56. Disconnect circuit 450 lead (16) from lower circuit breaker (17). 57. Disconnect circuit 450B lead (18) from upper circuit breaker (19). 58. Remove circuit 450 (16) and 450B (18) leads and two grommets (20) from distribution box (7). Discard grommets.