TM 9-2350-261-20-2 REPLACE REAR MAIN WIRING HARNESS (M577A2 AND M1068 ONLY) — Continued 0287 00 32. If NBC unit is installed, connect circuit 415 lead (1) to NBC unit. 33. Connect circuit 402 lead (2) to personnel heater wiring harness. 34. Connect circuit 400 lead (3) to personnel heater control box. 35. Install six clamps (4) on circuit 48 lead (5) on six weldnuts (6). Secure clamps with six screws (7). 36. Install two new lockwashers (8), circuit 48 capacitor (9), and ground lead (10) on weldnut (11). Secure with screw (12). 37. Install circuit 48 lead (5) on bracket (13). Secure with four screws (14) and nuts (15). 0287 00-21