TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 37 of 1012
TM 9-2350-261-20-2 REPLACE THERMOSTAT, HOUSING, AND DEAERATION ELBOW 0200 00 THIS WORK PACKAGE COVERS: Removal (page 0200 00-1). Installation (page 0200 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) Socket Wrench Set (WP 0780 00, Item 96) Torque Wrench (WP 0780 00, Item 102) M a t e r i a l s / P a r t s Sealing compound (WP 0782 00, Item 65) Sealing compound (WP 0782 00, Item 62) Deaeration elbow gasket Housing gasket Key washer (2) Lockwasher (6) Thermostat gasket P e r s o n n e l R e q u i r e d Unit Mechanic E q u i p m e n t C o n d i t i o n Engine stopped/shutdown (see your -10) Carrier blocked Trim vane lowered and power plant front access door open (see your -10) Cooling system drained (WP 0193 00) Remove air cleaner housing and element (WP 0185 00) REMOVAL 1. Loosen two clamps (1). Disconnect hose (2) from elbow (3) and hose (4) from elbow (5). 0200 00-1